Operation CHARM: Car repair manuals for everyone.

P2007

DTC P2007 INTAKE MANIFOLD RUNNER CONTROL STUCK CLOSED (BANK 2)

1. OUTLINE OF DIAGNOSIS
Detect the malfunction of tumble generator valve motor function.
Judge close fixing malfunction when the opening degree is small even after finishing the tumble generator valve open driving.

2. ENABLE CONDITION






3. GENERAL DRIVING CYCLE
Always perform the diagnosis continuously.

4. DIAGNOSTIC METHOD

- Abnormality Judgment
If the duration of time while the following conditions are met is longer than the time indicated, judge as NG.






Time Needed for Diagnosis: 3000 ms

Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.

- Normality Judgment
Judge as OK and clear the NG if the continuous time while the following conditions are established is more than the predetermined time.






Time Needed for Diagnosis: Less than 1 second