Evaporative Shut Valve: Service and Repair
Shut ValveREMOVAL
WARNING: Place "NO OPEN FLAMES" signs near the working area.
CAUTION: Be careful not to spill fuel.
1. Remove the fuel filler pipe.
2. Disconnect the evaporation hose from the shut valve.
3. Remove the shut valve from the fuel filler pipe.
INSTALLATION
Install in the reverse order of removal.
Tightening torque: 4.5 N.m (0.5 kgf.m, 3.3 ft.lb)