Removal and Replacement
GeneratorREMOVAL
1. Disconnect the ground cable from battery.
2. Remove the V-belt covers.
3. Disconnect the connector and terminal from generator.
4. Remove the front side belts.
5. Remove the bolts which install the generator onto bracket.
INSTALLATION
Install in the reverse order of removal.
CAUTION: Check and adjust the front side belt tension.
Tightening torque: 25 N.m (2.5 kgf.m, 18.4 ft.lb)
Tightening torque: 13 N.m (1.3 kgf.m, 9.6 ft.lb)