INSPECTION

1. CHECK BACK-UP LIGHT SWITCH (MT MODEL)

1. Disconnect the back-up light switch connector.
2. Measure the resistance between back-up light switch terminals.

Preparation tool: Circuit tester






3. Replace the back-up light switch if the inspection result is not within the standard value.

2. CHECK INHIBITOR SWITCH (AT/CVT MODEL)

1. Disconnect the inhibitor switch connector.
2. Measure the resistance between inhibitor switch terminals.

Preparation tool: Circuit tester






3. Replace the inhibitor switch if the inspection result is not within the standard value.