Removal and Replacement
StarterREMOVAL
1. Disconnect the ground cable from battery.
2. Remove the air intake boot assembly. (non-turbo model)
3. Remove the intercooler. (turbo model)
4. Disconnect connector (B) and terminal (A) from starter.
5. Remove the starter from transmission.
NOTE: For the MT model, a bolt is used in place (A).
INSTALLATION
Install in the reverse order of removal.
NOTE: For the MT model, a bolt is used in place (A).
Tightening torque: 50 N.m (5.1 kgf.m, 36.9 ft.lb)
Tightening torque: 10 N.m (1.0 kgf.m, 7.4 ft.lb)