P014C
DTC P014C O2 SENSOR SLOW RESPONSE - RICH TO LEAN (BANK 1 SENSOR 1)1. OUTLINE OF DIAGNOSIS
Detect the slow response of front oxygen (A/F) sensor.
For diagnosis, detect the trouble by processing the � waveform in normal driving without forcibly changing the target air fuel ratio.
2. COMPONENT DESCRIPTION
3. ENABLE CONDITIONS
4. GENERAL DRIVING CYCLE
Perform diagnosis only once in a city driving including normal acceleration and deceleration.
5. DIAGNOSTIC METHOD 1
Detect the malfunction by checking "Cumulative value of time when Lambda changes from lean -> rich" in comparison to "Time during which diagnosis is in progress".
- Abnormality Judgment
Judge as NG when the following conditions are established.
Time Needed for Diagnosis: 90 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Time Needed for Diagnosis: 90 seconds
6. DIAGNOSTIC METHOD 2
Detect the malfunction by the cumulative value obtained from the amount of variation in Lambda change.
- Abnormality Judgment
Judge as NG when the following conditions are established.
Time Needed for Diagnosis: 90 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG if the following conditions are established.
Time Needed for Diagnosis: 90 seconds