Refrigerant: Testing and Inspection
Refrigerant Leak CheckINSPECTION
PREPARATION TOOL:
Manifold gauge set
Electronic leak detector
1. Attach the manifold gauge set.
1. Confirm that all valves are fully closed.
2. Install the low/high pressure hoses to the service ports on the low/high pressure sides of the vehicle respectively.
CAUTION: Confirm that the connections are secure.
3. Start the engine to operate the A/C system for approx. 10 minutes, and check that the high-pressure side shows at least 0.69 MPa (7.0 kgf/sq.cm, 100 psi).
2. Stop the engine to start the leak test.