Operation CHARM: Car repair manuals for everyone.

Fluid Pressure Sensor/Switch: Testing and Inspection

INSPECTION

1) Remove the instrument panel lower cover.
2) Start and warm up the engine.
3) Shift the select lever to "P" or "N" range.
4) Depress the brake pedal and hold it.
5) Check the voltage of secondary pressure sensor with engine idling.

Connector & terminal
(B54) No. 12 (+) - No. 25 (-):

Standard
0.7 - 0.9 V