Removal and Replacement
GeneratorREMOVAL
1. Remove the collector cover.
2. Disconnect the ground cable from battery.
3. Disconnect the connector and terminal B from the generator, and remove the harness cover from the collector cover bracket.
4. Remove the V-belts.
5. Remove the collector cover bracket.
6. Remove the generator.
INSTALLATION
Install in the reverse order of removal.
CAUTION: Check and adjust the V-belt tension.
Tightening torque: 25 N.m (2.5 kgf-m, 18.4 ft-lb)
Tightening torque:
T1: 6.4 N.m (0.7 kgf-m, 4.7 ft-lb)
T2: 25 N.m (2.5 kgf-m, 18.4 ft-lb)
Tightening torque: 16 N.m (1.6 kgf-m, 11.8 ft-lb)