Wiper Blade Heater: Testing and Inspection
INSPECTION
1. SYSTEM INSPECTION
NOTE: Wiper deicer system can be customized on the Subaru Select Monitor.
*: When one of the following conditions occurs, continuous operation is suspended and turned off after 15 minutes.
- Ambient temperature at 5°C (41°F) or more continues for 10 seconds.
- Malfunction occurs on ambient sensor.
- Vehicle speed of 15 km/h (9 MPH) or less continues 15 minutes (OFF when conditions are met)
- Malfunction occurs in CAN communication.
- Battery voltage remains at 10 V or less for 30 seconds.
2. HEAT WIRE INSPECTION
Refer to "HEAT WIRE INSPECTION" of "Rear Window Defogger System".
NOTE: For heat wire inspection, removing and installing the instrument panel assembly are required.