Fluid Pressure Sensor/Switch: Testing and Inspection
INSPECTION1) Remove the instrument panel lower cover.
2) Start and warm up the engine.
3) Shift the select lever to "P" or "N" range.
4) Depress the brake pedal and hold it.
5) Check "secondary pressure sensor voltage" by using Subaru Select Monitor while the engine is idling.
Standard
Approx. 0.8 V
6) Check "secondary pressure sensor voltage" with engine stopped and ignition switch turned on by using Subaru Select Monitor. Subaru Select Monitor/Operation
Specification:
Approx. 0.5 V