Overhaul

Select Lever

DISASSEMBLY

1) Shift the select lever to "N" range.
2) Lower the grip cover.





3) Remove the grip pin.





4) Remove the grip assembly.





5) Remove the grip cover.





6) Remove the indicator light and then remove the bulb.





7) Remove the shift lock solenoid assembly.





8) Remove the indicator assembly.





9) Remove the bulb case.





10) Remove the plate light guide.





11) Remove the position plate.





12) Remove the blind assembly.





13) Remove blind A and B.





14) Remove the clip while being careful not to break the pin, and remove all switches.





15) Remove the connector from the base assembly using a flat tip screwdriver.





16) Remove all terminals from the connectors using a flat tip screwdriver.





17) Remove the solenoid unit from the lock lever bracket.





18) Remove the bushing.





19) Remove the lock lever bushing.





20) Remove the lock lever.





21) Remove the release rod and spring.





22) Remove the cable bracket.





23) Remove the spacer.





24) Remove the dust cover and dust cover bracket.





25) Remove the spacer.





26) Using a press, remove the shift position pin.





27) Remove the clips, then remove the shaft.





28) Remove the arm assembly.
29) Remove the bushing.





30) Remove the selector arm assembly.





31) Remove the clip while being careful not to break the pin, then remove the shift button switch.





32) Remove the select shaft.





33) Remove the tube cross plate.





34) Remove the mode change switch.





35) Remove the detent check block.





ASSEMBLY

1) Clean all the parts before assembly.
2) Apply specified greases or equivalent to each part.
^ Multemp AC-D or equivalent





^ Multemp SH-W or equivalent





^ Permalube BAN-5 or equivalent





3) Assemble in the reverse order of disassembly.

NOTE:
^ Refer to "COMPONENT" for each tightening torque.
^ When pressing in the shift position pin, insert from the left side of the vehicle.
^ Affix the harness of the shift button switch and the mode change switch at the marked positions.





^ Connect the terminals of all switches to the respective connectors.





4) After completing installation, shift the select lever from the "P" range to the "D" range, then check whether or not the selection indicator in the combination meter and the select lever position matches. Also check whether the pointer and position mark matches, and what the operating force is.