Camshaft Position Sensor: Testing and Inspection
Connecting Voltmeter:
- With ignition switch OFF, disconnect ECM connector (Yellow).
- Connect voltmeter between "B1" terminal of green connector (connected) and "A13" terminal of yellow connector (disconnected).
- Remove distributor cap, rotor and shield cover.
NOTE: Check to make sure that magnet is free from any metal particles.
Magnetic Flux Conditions For Voltage Check:
- Check voltage with signal rotor inserted between hall element and magnet ("A") and without it ("B") respectively.
"A" = Battery voltage
"B" = Zero (0) volts
- If check result is not satisfactory, repair wire harness or replace CAS.
- After checking, connect ECM coupler securely install distributor cap.