Control Module HVAC: Testing and Inspection
INSPECTION OF A/C CONTROLLER AND ITS CIRCUITSCAUTION: A/C controller and ECM cannot be checked by itself. It is strictly prohibited to connect voltmeter or ohmmeter to A/C controller and ECM with couplers disconnected from it.
A/C Controller:
A/C Controller (1) and its circuits can be checked at A/C controller wiring couplers by measuring voltage.
VOLTAGE CHECK
Fig. A, Fig. B, Fig C.:
1. Remove A/C controller (1) from vehicle (refer to "A/C CONTROLLER").
2. Remove ECM (2) from vehicle.
3. Connect A/C controller couplers to A/C controller and connect ECM couplers to ECM.
4. Check each terminal voltage with couplers connected by referring to "A/C CONTROLLER VOLTAGE VALUES TABLE".
NOTE: For "Fig. A", "Fig. B", "Fig. C" in the figure, refer to "A/C CONTROLLER VOLTAGE VALUES TABLE".