A/C - Evaporator Core Freezes Up

Section Title: HVAC
TSB No. TS 03 03273R

Division: Automotive
Category: Technical

SUBJECT:
REVISED REPAIR PROCEDURE FOR A/C EVAPORATOR FREEZE-UP DURING USE

MODEL(S):
GRAND VITARA, GRAND VITARA XL-7

YEAR:
1999-2002 GRAND VITARA
2001-2002 GRAND VITARA XL-7

CONDITION:

A/C stops cooling then begins cooling again after several minutes and/or water dripping from evaporator case on passenger side floor.

CAUSE:

A/C evaporator freeze-up during extended use and/or water dripping onto the carpet from condensation building on the outside of the evaporator case.

CORRECTION:





Remove A/C evaporator core as outlined in the applicable year and model Service Manual. Remove thermistor probe and move probe above row 7 and clip in row 9 as shown in the photographs.