Operation CHARM: Car repair manuals for everyone.

System Operation

MALFUNCTION INDICATOR LAMP (MIL) CHECK





Refer to the same item in Powertrain Management; Computers and Control Systems for checking procedure.

"O/D OFF" LAMP CHECK
1. Check that O/D cut switch button is at OFF position (pushed).
2. Turn ignition switch ON.
3. Check that "O/D OFF" lamp lights for about 2 - 4 sec. and then goes OFF.
If anything faulty is found, advance "DIAGNOSTIC FLOW TABLE B-1 or B-2 "O/D OFF" LAMP CIRCUIT CHECK". Symptom Related Diagnostic Procedures

POWER" LAMP CHECK
1. Check that Power/Normal change switch button is at Normal position.
2. Turn ignition switch ON.
3. Check that "POWER" lamp lights for about 2 - 4 sec. and then goes OFF.
If anything faulty is found, advance "DIAGNOSTIC FLOW TABLE B-3 or B-4 "POWER" LAMP CIRCUIT CHECK". Symptom Related Diagnostic Procedures