Scan Tool Data Definitions
Scan Tool Data DefinitionsTEMP CONT SWITCH: Position of temperature control selector of HVAC control module.
EVAPORATOR TEMP: Temperature of air passed through evaporator.
COOLANT TEMP: Engine coolant temperature detected by engine coolant temperature sensor.
MODE CONT SWITCH: Position of airflow selector of HVAC control module.
FAN CONT SWITCH: Position of air speed selector of HVAC control module.
FAN DESIRE VOLT: Voltage for blower motor.
AIR MIX POS SENSOR: Input signal from position sensor in temperature control actuator.
MODE POS SENSOR: Input signal form position sensor in air flow control actuator.
A/C CONT SIG (ON or OFF): State of A/C indicator lamp.
BLOWER FAN LOAD (ON or OFF):
- ON: Position of blower speed selector is 1st or 2nd position.
- OFF: Position of blower speed selector is more than 3rd position.
AIR INTAKE MODE (FRE, REC or MIX): State of air intake mode
A/C INDICATOR LAMP (ON or OFF): State of A/C indicator lamp
FRE INDICATOR LAMP (ON or OFF): State of fresh air (FRE) indicator lamp
REC INDICATOR LAMP (ON or OFF): State of recirculation air (REC) indicator lamp
REAR DEF INDICATOR: State of rear defogger indicator lamp
FUEL TYPE (GASOLINE or DIESEL): Type of fuel which should be used