Turn Signal and Hazard Warning Lights System Circuit Inspection
TURN SIGNAL AND HAZARD WARNING LIGHTS SYSTEM CIRCUIT INSPECTION1. Disconnect negative ( ) cable from battery.
2. Disconnect turn signal and hazard warning relay (1) connector "E218".
3. Connect negative ( ) cable to battery.
4. Confirm that right or left side turn signal lights turn on when connecting "E218-4" terminal to "E218-2" or "E218-3" terminal with service wire. If turn signal light does not turn on, check bulb or repair applicable circuit.