Component Tests and General Diagnostics
Keyless Entry System Operation Inspection1. Confirm that power door lock system operates normally, refer to Power Door Lock System Operation Inspection. Power Door Lock System Operation Inspection
2. All doors are closed and unlocked.
3. Check the following operation:
a. Push "lock" button (1) on transmitter (2) or remote controller once, and check all doors lock and hazard waning lights flash once.
b. Push "unlock" button (3) on transmitter (2) or remote controller twice, and check all doors unlock and hazard waning lights flash twice and interior light turns on several seconds with the interior light switch in the middle position.
If malfunction is found, go to Keyless Entry System Symptom Diagnosis (If Equipped). Keyless Entry System Symptom Diagnosis