Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) Exhaust
Camshaft Position Actuator Solenoid Valve Solenoid Replacement - Bank 1 (Right Side) ExhaustRemoval Procedure
1. Remove the air cleaner assembly. Refer to [Air Cleaner Assembly Replacement].
2. Disconnect the engine wiring harness electrical connector (5) from the bank 1 exhaust camshaft position (CMP) actuator solenoid valve.
3. Remove the CMP actuator solenoid valve bolt.
4. Remove the CMP actuator solenoid valve.
5. Inspect the CMP actuator solenoid valve seal and replace as necessary.
Installation Procedure
1. Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
2. Install the CMP actuator solenoid valve.
CAUTION: Refer to [Fastener Notice].
3. Install the CMP actuator solenoid valve bolt.
Tightening torque
Tighten the bolt to 10 N.m (89 lb.in).
4. Connect the engine wiring harness electrical connector (5) to the bank 1 exhaust CMP actuator solenoid valve.
5. Install the air cleaner assembly. Refer to [Air Cleaner Assembly Replacement].