Operation CHARM: Car repair manuals for everyone.

Torque Converter Housing Installation

Torque Converter Housing Installation





1. Remove the case fluid passage seal (89).
2. Install a NEW case fluid passage seal (89) into the transmission case assembly.





3. Apply a 3 mm (1/8 in) bead of sealant GM P/N 89020326 (Canadian P/N 89021188) on the inside of the bolt holes of the scaling flange of the torque converter housing assembly.





4. Remove the holding fixture bolt (1) to allow clearance to install the torque converter housing assembly.
5. Install the torque converter housing assembly to the transmission case assembly.





6. Apply threadlocker GM P/N 12345382 (Canadian P/N 10953499), to the threads of all the torque converter housing bolts.
7. Install the 11 - M8 x 1.25 x 30 mm bolts (4) and hand tighten.
8. Install the 2 - M8 x 1.25 x 30 mm bolt/studs (3) and hand tighten.
9. Install the 2 - M8 x 1.25 x 35 mm bolts (6) and hand tighten.
10. Install the 1 M8 x 1.25 x 45 mm bolt (7) and hand tighten.
11. Install the 1 M8 x 1.25 x 30 mm TORX 40 bolt (8) and hand tighten.





CAUTION:
Refer to [Fastener Notice]


12. Tighten the 17 torque converter housing bolts in sequence.
Tightening torque
Tighten the torque converter housing bolts to 29 Nm (21 ft. lbs.).