Transfer Control Unit (M/T)
P1816 PNP Switch (M/T)Description
The M/T PNP switch signals neutral position to the transfer control unit. DTC P1816 will set when the M/T PNP switch signal is malfunctioning.
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
Step 1:
Diagnosis Procedure
Step 1:
Steps 1-3:
Steps 3-4:
Steps 4-5:
Component Inspection
1) Turn ignition switch "OFF". (Stay for at least 5 seconds.)
2) Disconnect neutral position switch harness connector.
3) Remove neutral position switch.
4) Push and release neutral position switch and check continuity between neutral position switch terminals 1 and 2.
5) If NG, replace the neutral position switch.