Precautions in Sensor Calibration
Precautions in Sensor Calibration
ESP(R) control module stores calibration points data of yaw rate / G sensor assembly and master cylinder pressure sensor. Steering angle sensor stores calibration point data of itself.
Traction control system, stability control system, hill descent control (if equipped) and hill hold control (if equipped) use these sets of data.
When the following operation is done, calibration should be performed since the original calibration points are deleted.
Perform sensor calibration according to Programming and Relearning Sensor Calibration of ESP(R) Components.