Oxygen Sensor: Testing and Inspection
1. Disconnect sensor coupler.2. Using ohmmeter, measure resistance between terminals "VB" and "GND" of sensor coupler.
NOTE: Temperature of sensor affects resistance value largely. Make sure that sensor heater is at correct temperature.
Resistance of oxygen sensor heater: 11.7 - 15.6 ohms at 20°C, 68°F
- If found faulty, replace oxygen sensor.
3. Connect sensor coupler securely.