Dismounting and Remounting
DISMOUNTING1. Disconnect negative cable at battery.
2. Disconnect "B" terminal wire and coupler from generator.
3. Remove generator mounting bolt and loosen drive belt adjusting bolt.
4. Remove generator cover.
5. Remove generator bracket, and then remove generator.
REMOUNTING
Reverse above procedure giving specified tension to drive belt.
Tightening Torque
(a): 23 N.m (2.3 kg-m, 16.5 lb-ft)
(b): 5.5 N.m (0.55 kg-m, 4.0 lb-ft)
(c): 8 N.m (0.8 kg-m, 6.0 lb-ft)