Oxygen Sensor: Testing and Inspection
HEATED OXYGEN SENSOR (Sensor-1 and Sensor-2)
Oxygen Sensor Heater Inspection
1) Disconnect sensor coupler.
2) Using ohmmeter, measure resistance between terminals "VB" and "GND" of sensor coupler.
NOTE: Temperature of sensor affects resistance value largely. Make sure that sensor heater is at correct temperature.
Resistance of oxygen sensor heater: 11.7 - 15.6ohms at 20°C, 68°F.
If found faulty, replace oxygen sensor.
3) Connect sensor coupler securely.