Dismounting and Remounting
DISMOUNTING1. Disconnect negative cable at battery.
2. Remove air cleaner outlet hose, engine under cover (right side) and exhaust pipe No.2.
3. Disconnect "B" terminal wire and coupler from generator.
4. Remove generator belt.
5. Remove generator cover.
6. Remove mounting No.1 and No.2 bolts or bracket bolts. (Remove bracket bolts instead of No.2 bolt only when No.1 bolt can not be removed.)
7. Remove generator.
REMOUNTING
Reverse dismounting procedure.
Tightening Torque