Oxygen Sensor: Testing and Inspection
HEATED OXYGEN SENSOR (Sensor-1 and Sensor-2)Oxygen Sensor Heater Inspection
1. Disconnect sensor coupler.
2. Using ohmmeter, measure resistance between terminals "V(B)" and "GND" of sensor coupler.
NOTE: Temperature of sensor affects resistance value largely. Make sure that sensor heater is at correct temperature.
Resistance of oxygen sensor heater: 11.7 - 14.3 ohms at 20 °C, 68 °F
If found faulty, replace oxygen sensor.
3. Connect sensor coupler securely.