Main Relay (Computer/Fuel System): Testing and Inspection
MAIN RELAY1. Disconnect negative cable at battery.
2. Remove main relay from relay box.
3. Check resistance between each two terminals as in table. If check results are as specified, proceed to next operation check. If not, replace.
4. Check that there is continuity between terminals "A" and "B" when battery is connected to terminals "C" and "D".
If found defective, replace.