EGR Valve Removal and Installation
EGR Valve Removal and Installation
Removal
1) Disconnect negative cable at battery.
2) Disconnect EGR valve coupler.
3) Remove EGR valve (1) and gasket (2) from intake manifold (3).
Installation
EGR Valve Inspection
Reverse removal procedure noting the following.
- Clean mating surface of valve and intake manifold (3).
- Use new gasket (2).