Fuel Tank Pressure Sensor Check
Operation Check1. Remove fuel tank pressure sensor (1) from fuel tank.
2. Check sensor air vent (5) hole and pressure passage for clog. Clean if clogged.
3. Arrange 3 new 1.5 V batteries (2) in series (check that total voltage is 4.5 - 5.0 V) and connect its positive terminal to "Vin" terminal of sensor and negative terminal to "Ground" terminal. Then check voltage between "Vout" and "Ground".
Also, check if voltage reduces when vacuum is applied up to 6.6 kPa (50 mmHg) by using vacuum pump (3) and if it increases when positive pressure is applied up to 6.6 kPa (50 mmHg) by using hand pump. If measured voltage doesn't show such characteristic as shown in the figure, replace.
- For G16 Engine
- For J18 Engine
CAUTION:
- As connection to wrong terminal will cause damage to tank pressure sensor; make absolutely sure to connect properly as shown in the figure.
- Do not apply pressure higher than 98 kPa (742 mmHg) to tank pressure sensor by hand pump. Applying excessive pressure will break it.