Dismounting and Remounting
Dismounting1. Disconnect negative cable (2) at battery (1).
2. Remove air cleaner outlet hose, engine under cover (right side) and exhaust pipe No.2.
3. Disconnect "B" terminal wire (1) and coupler (2) from generator.
4. Remove generator belt referring to "Generator Belt Removal and Installation: J18 Engine".
5. Remove generator cover (4).
6. Remove mounting No.1 and No.2 bolts (6) or bracket bolts (7). (Remove bracket bolts instead of No.2 bolt only when No.1 bolt (5) can not be removed.)
7. Remove generator.
Remounting
Reverse dismounting procedure.