P1112
DTC P1112 Intake Air Temperature Intermittent Low VoltageCircuit Diagram:
Circuit Description
The Intake Air Temperature (IAT) sensor is a thermistor which measures the temperature of the air entering the engine. The Engine Control Module (ECM) applies 5 volts through a pull-up resistor to the IAT sensor. When the intake air is cold, the resistance is high, and the ECM will monitor a high signal voltage on the IAT signal circuit. If the intake air is warm, the sensor resistance is lower causing the ECM to monitor a lower voltage. Diagnostic Trouble Code (DTC) P1111 will set when the ECM detects an intermittent high signal voltage in the intake air temperature sensor signal circuit or sensor.
Conditions for Setting the DTC
- IAT is greater than 149 °C (300 °F).
- DTC P0502 not set
- Engine has been running for over two minutes.
- Vehicles speed is greater than or equal to 50 km/h (31 mph).
Action Taken When the DTC Sets
- The ECM will substitute a default value for IAT.
- The ECM will store conditions which were present when the DTC set as Failure Records data only. This information will not be stored as Freeze Frame data.
- The Malfunction Indicator Lamp (MIL) will not illuminate.
- A history DTC is stored.
Conditions for Clearing the MIL/DTC
- A history DTC will clear after 40 consecutive warm-up cycles without a fault.
- DTC(s) can be cleared by using the scan tool.
- Disconnecting the ECM battery feed for more than 10 seconds.
Diagnostic Aids
Check for the following conditions:
- Poor connection at the ECM. Inspect harness connectors for backed-out terminals, improper mating, broken locks, improperly formed or damaged terminals, and poor terminal-to-wire connection.
- Damaged harness. Inspect the wiring harness for damage. If the harness appears to be OK, observe the IAT display on the scan tool while moving connectors and wiring harnesses related to the IAT sensor. A change in the IAT display will indicate the location of the fault.
- Reviewing the Fail Records vehicle mileage since the diagnostic test last failed may help determine how often the condition that caused the DTC to be set occurs. This may assist in diagnosing the condition.
- Use the Temperature vs. Resistance Values table to evaluate the possibility of a skewed sensor. Refer to Temperature vs Resistance. [1][2]Computers and Control Systems
Test Description
Number(s) below refer to the step number(s) on the Diagnostic Chart.
1. The On-Board Diagnostic (OBD II) System Check prompts the technician to complete some basic checks and store the freeze frame and failure records data on the scan tool if applicable. This creates an electronic copy of the data taken when the malfunction occurred. The information is then stored on the scan tool for later reference.
2. Verifies the fault is present.
3. If DTC P1112 can be repeated only by duplicating the Fail Records conditions, refer to the Temperature Vs. Resistance Value Chart. [1][2]Computers and Control Systems The chart may be used to test the IAT sensor at various temperatures to evaluate the possibility of a "shifted" sensor that may be shorted above or below a certain temperature. If this is the case, replace the IAT sensor.