Restraints - Except Advanced Air Bag
DTC B1061: AIR BAG Warning Lamp Circuit FailureWiring Diagram:
Wiring Diagram
CAUTION:
- Be sure to perform Air Bag Diagnostic System Check:Except Advanced Air Bag before starting diagnosis according to flow table. Air Bag Diagnostic System Check
- When measurement of resistance or voltage is required in this table, use a specified digital multimeter (Refer to Special Tool:Except Advanced Air Bag.) along with a correct terminal adapter from special tool (Connector test adapter kit).
- When a check for proper connection is required, refer to Inspection of Intermittents and Poor Connections:Except Advanced Air Bag. Inspection of Intermittents and Poor Connections
- If there is open circuit in the air bag wire harness, connector or terminal is found damaged, replace the wire harness, connector and terminal as an assembly.
DTC Will Set when
The voltage at the AIR BAG warning lamp circuit L70-30 terminal does not match the commanded state of the warning lamp driver for specified time.
Flow Test Description
STEP 1: This test rechecks AIR BAG warning lamp operation.
STEP 2: This test rechecks whether an abnormality is in SDM.
Step 1 - 2:
DTC Troubleshooting