Knock Sensor: Service and Repair
Knock Sensor Removal and InstallationRemoval
1. Disconnect the negative battery cable.
2. Remove the VIS vacuum tank.
3. Remove the wiring harness from the wiring support bracket.
4. Disconnect the knock sensor wiring harness connector.
5. Remove the knock sensor.
Installation
1. Installation should follow the removal procedure in the reverse order.
2. Install the knock sensor.
Tighten: Tighten the knock sensor retaining bolt to 18 - 20 N.m (13 - 15 lb-ft).
3. Install the VIS vacuum tank.
Tighten: Tighten the VIS vacuum tank retaining bolts to 7 - 9 N.m (62 - 80 lb-in.).