Comprehensive Component (Engine Output) Monitor
OBD System Description - Comprehensive Component Monitor (Engine Output)EST_Cylinder_1_Fault
DTC Description / Detecting Condition / Confirmation Procedure
P0351 refer to P0351
Monitor Strategy Description
Detects a short to ground, to battery or open circuit on ESC output.
Fault information provided by a current monitoring circuit.
Malfunction Criteria
Current below min. threshold = TRUE
OR
Current exceeds max. threshold = TRUE
OR
Time to min. threshold < 0.1406
Enable Conditions
No disabling Faults Present = FALSE
AND Engine Running = RUN
AND Ignition Voltage >= 11 V
AND Ignition Voltage <= 16 V
AND Enable Time delay >= 0.5 s
Time required
Detection Time
5.00 seconds failure out of 9.88 seconds sample period
Continuous Monitoring every 125.00 ms
Detection Samples
40 test failures within 80 test samples at 125. ms loop time
EST_Cylinder_2_Fault
DTC Description / Detecting Condition / Confirmation Procedure
P0352 refer to P0352
Monitor Strategy Description
Detects a short to ground, to battery or open circuit on ESC output.
Fault information provided by a current monitoring circuit.
Malfunction Criteria
Current below min. threshold = TRUE
OR
Current exceeds max. threshold = TRUE
OR
Time to min. threshold < 0.1406
Enable Conditions
No disabling Faults Present = FALSE
AND Engine Running = RUN
AND Ignition Voltage >= 11 V
AND Ignition Voltage <= 16 V
AND Enable Time delay >= 0.5 s
Time required
Detection Time
5.00 seconds failure out of 9.88 seconds sample period
Continuous Monitoring every 125.00 ms
Detection Samples
40 test failures within 80 test samples at 125. ms loop time