Expansion Valve: Service and Repair
Expansion Valve Removal and InstallationReference: HVAC Unit Components:Manual Type
Removal
1. Recover refrigerant from the A/C system with recovery and recycling equipment referring to "Recovery" in Operation Procedure for Refrigerant Charge:Manual Type.
2. Loosen a bolt (1) and remove pipes from expansion valve (2).
3. Loosen bolts (3) and remove expansion valve.
Installation
Reference: Expansion Valve Inspection:Manual Type
Reverse removal procedure noting the following instructions.
^ Apply compressor oil to O-ring of expansion valve and pipes.
^ Tighten expansion valve bolts to specified torque.
Tightening torque
Expansion valve bolt: 4.5 Nm (0.45 kg.m, 3.5 ft. lbs.)
^ Evacuate and charge the A/C system referring to "Evacuation" and "Charge" in Operation Procedure for Refrigerant Charge:Manual Type.