Backup Lamp Switch: Service and Repair
Back Up Light Switch Removal and InstallationRemoval
1. Remove battery and tray with ECM.
2. Disconnect back up light switch coupler (1).
3. Remove back up light switch.
Installation
1. Apply oil to new O-ring (1) and tighten back up light switch (2) to specified torque.
Tightening torque
Back up light switch a: 23 Nm (2.3 kgf-m, 17.0 ft. lbs.)
2. Connect back up light switch coupler.
3. Install battery and tray with ECM.