Inspection
Blower Motor Resistor Inspection
Blower Motor Resistor Removal and Installation
Measure each terminal-to-terminal resistance. If measured resistance is out of specification, replace blower motor resistor.
Blower motor resistor resistance
"H" - "MH": Approx. 0.43 ohms at 20 - 25 °C (68 - 77 °F)
"MH" - "ML": Approx. 0.6 ohms at 20 - 25 °C (68 - 77 °F)
"ML" - "L": Approx. 2.0 ohms at 20 - 25 °C (68 - 77 °F)