Generator Removal and Installation
Generator Removal and Installation
Removal
1) Disconnect negative (-) cable from battery.
2) Remove intake manifold. Intake Manifold Removal and Installation
3) Remove accessory drive belt. Removal and Installation
4) Disconnect "B" terminal wire (1) and connector (2) from generator (3).
5) Remove generator (3).
Installation
Generator Components
Generator Inspection
Reverse removal procedure noting the following.
Tighten generator bolts, "B" terminal wire nut and power steering pump stay bolt to specified torques.
Tightening torque
"B" terminal wire nut (a): 11 Nm (1.1 kgf-m, 8.5 lbf-ft)
Generator bolt (b): 45 Nm (4.6 kgf-m, 33.5 lbf-ft)
Power steering pump stay bolt (c): 25 Nm (2.5 kgf-m, 18.5 lbf-ft)