Starting Motor Removal and Installation
Starting Motor Removal and Installation
Removal
1) Disconnect negative (-) cable from battery.
2) Remove air cleaner assembly. Air Cleaner Assembly Removal and Installation
3) Remove air cleaner bracket (1).
4) Disconnect magnetic switch lead wire (1) and starting motor cable (2) from starting motor.
5) Remove starting motor mounting bolts (3).
6) Remove starting motor (4).
Installation
Starting Motor Inspection
Reverse removal procedure noting the following.
- Tighten starting motor mounting bolts (3) and starting motor cable nut (5) to specified torques.
Tightening torque
Starting motor cable nut (a): 11 Nm (1.1 kgf-m, 8.5 lbf-ft)
Starting motor mounting bolt (b): 45 Nm (4.6 kgf-m, 33.5 lbf-ft)