Main Heated Oxygen Sensor
INSPECTIONOxygen Sensor Heater Resistance Inspection
1. Using an ohmmeter measure the resistance between the terminals +B and HT.
Resistance: 5 - 7 ohms at 20°C (68°F).
2. If the resistance is not as specified, replace the Heated Oxygen Sensor.
Feedback Voltage Inspection
1. Warm engine up to operating temperature.
2. Connect a voltmeter to the DLC1 terminals VF1 and E1. When called for in the test, use a jumper wire to connect between terminals TE1 and E1.
���Heated Oxygen Sensor Circuit Diagnosis:
3. Perform test as shown in the diagnostic chart.