Reading and Clearing Diagnostic Trouble Codes
Except Code 41
1. Turn ignition switch Off, then disconnect battery ground cable or ECU-B fuse for 10 seconds or more.
2. When connecting battery after cancelling malfunction code, ensure ignition switch in Lock position. If battery cable is connected with ignition switch in On or ACC position, diagnosis system may malfunction.
3. The lower the temperature, the longer the battery ground cable must be left off.
Code 41
This code clearing method may be used for all codes.
1. Connect suitable service wires on check connector DLC1 terminals Tc and AB.
2. Turn ignition switch to ACC or On, then wait about 6 seconds.
3. Starting with Tc terminal, apply body ground alternately to terminal Tc and AB twice, each in cycles of 1.0 second.
4. Continuously apply ground to terminal Tc.
NOTE: When alternating between body ground to terminals Tc and AB release one from body ground and immediately apply it to the other terminal within 0.2 second. If code does not clear, repeat procedure until all codes are cleared.