Air Flow Meter/Sensor: Testing and Inspection
ON-VEHICLE INSPECTION
Measure resistance of volume air flow meter.
- Disconnect the connector from the volume air flow meter.
- Using an ohmmeter. measure the resistance between each terminal.
If not within specification. replace the volume air flow meter.
- Reconnect the volume air flow meter connector.
OFF-VEHICLE INSPECTION
Measure resistance of volume air flow meter.
- Using an ohmmeter, measure the resistance between each terminal by moving the measuring plate.
HINT: Resistance between terminals E2 and VS will change in a wave pattern as the measuring plate slowly opens.