Service Hints
D16 DOOR LOCK ECU
6-GROUND: Always approx. 12 Volts
11-GROUND: Always Continuous
8-GROUND: Approx. 12 Volts with Ignition SW at ON position
7, 14-GROUND: Continuous with door opened
5-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF, but if a door is opened in this 60 seconds period, voltage will drop to 0 Volts
D14, D15 DOOR COURTESY SW
1-GROUND: Continuous with door opened
P 4 POWER WINDOW MASTER SW
4-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF, but if a door is opened in this 60 seconds period, voltage will drop to 0 Volts
P 5 POWER WINDOW MASTER SW
6-GROUND: Always Continuous
9-GROUND: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 seconds after the Ignition SW is turned OFF, but if a door is opened in this 60 seconds period, voltage will drop to 0 Volts
3-GROUND: Approx. 12 Volts with Ignition SW at ON position and Master SW at UP position
4-GROUND: Approx. 12 Volts with Ignition SW at ON position and Master SW at DOWN or AUTO DOWN position
WINDOW LOCK SW
Open with Window Lock SW at LOCK position