Operation CHARM: Car repair manuals for everyone.

Service Hints

D17 DOOR LOCK CONTROL RELAY
2-Ground: Always Approx. 12 Volts
11-Ground: Always Continuous
8-Ground: Approx. 12 Volts with Ignition SW at ON position
7, 14-Ground: Continuous with Door opened
5-Ground: Approx. 12 Volts with Ignition SW ON and stay at 12 Volts for 60 Seconds after the Ignition SW is turned OFF, but if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts

D15, D16 DOOR COURTESY SW LH, RH
1-Ground: Continuous with Door opened

P 7 POWER WINDOW MASTER SW
6-Ground: Always Continuous
9-Ground: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF, but if a Door is opened in this 60 Second period, Voltage will drop to 0 Volts
3-Ground: Approx. 12 Volts with Ignition SW at ON position and master SW at UP position
4-Ground: Approx. 12 Volts with Ignition SW at ON position and master SW at Down or Auto Down position

WINDOW LOCK SW
Open with Window Lock SW at Lock position