Oxygen Sensor: Testing and Inspection
INSPECT HEATER RESISTANCE OF HEATED OXYGEN SENSORS.(Bank 1, Sensor 1, Bank 1 Sensor 2)
- Disconnect the oxygen sensor connector.
- Using an ohmmeter, measure the resistance between the terminals +B and HT.
Resistance: At 20°C (68°F): 11 - 16 Ohms
- If the resistance is not as specified, replace the sensor.
Torque: 20 Nm (14 ft lb)
- Reconnect the oxygen sensor connector.