Service Hints
F 6 4WD ECU16-Ground: Always Approx. 12 Volts
8-Ground: Always Continuous
5-Ground: 4 Pulses with 1 Rotation of the meter cable
15-Ground: 2 Volts or less with 2-4 Select SW ON
14-Ground: 2 Volts or less with detection SW (Transfer L4 Position) ON and Transfer Shift Lever at L4 position
T 3 2-4 SELECT SW
1-2: Closed with 2-4 select SW ON
P 1 A/T INDICATOR SW [PARK/NEUTRAL POSITION SW]
4-7: Closed with A/T shift Lever at P position