Air Flow Meter/Sensor: Service and Repair
REMOVAL1. REMOVE AIR CLEANER CAP WITH MAF METER
- Disconnect the MAF meter connector, IAT sensor connector and wire clamp.
- Loosen the air cleaner hose clamp.
- Disconnect the air hose from the air cleaner cap.
- Loosen the 4 clips and remove the air cleaner cap together with the MAF meter.
2. REMOVE MAF METER FROM AIR CLEANER CAP
- Remove the 4 nuts, MAF meter and gasket.
INSTALLATION
1. INSTALL MAF METER TO AIR CLEANER CAP
- Place a new gasket on the air cleaner cap.
- Install the MAF meter with the 4 nuts.
Torque: 8.5 N.m (85 kgf.cm, 74 in.lbf)
2. INSTALL MAF METER WITH AIR CLEANER CAP