Operation CHARM: Car repair manuals for everyone.

Power Window

I15-A, I16-B INTEGRATION RELAY
11-Ground: Always Approx. 12 Volts
6-Ground: Approx. 12 Volts with Ignition SW at ON position
A-5-Ground: Continuity with Front LH Door opened

POWER RELAY
2-1: Closed with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts

D16 DOOR COURTESY SW FRONT LH
1-Ground: Continuity with Door opened

P 4 POWER WINDOW CONTROL SW FRONT RH
5-Ground: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts

P 5, P 6 POWER WINDOW CONTROL SW REAR LH, RH
5-Ground: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts for 60 Seconds after the Ignition SW is turned OFF,
But if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts

P 7 POWER WINDOW MASTER SW
2-Ground: Always continuity
8-Ground: Approx. 12 Volts with Ignition SW ON and stays at 12 Volts fro 60 Seconds after the Ignition SW is turned OFF, but if a Door is opened in this 60 Seconds period, voltage will drop to 0 Volts
6-Ground: Approx. 12 Volts with Ignition SW at ON position and master SW at Up position
13-Ground: Approx. 12 Volts with Ignition SW at ON position and master SW at Down or Auto Down position

WINDOW LOCK SW
Open with Window Lock SW at Lock position